Constant improvement
Our company pays great attention to improve our CEM exam materials: Certified Energy Manager (CEM). Our aim is to develop all types study material about the official exam. Then you will relieve from heavy study load and pressure. Also, our researchers are researching new technology about the CEM learning materials. After all, there always exists fierce competition among companies in the same field. Once we stop improve our CEM study guide, other companies will soon replace us. The most important reason is that we want to be responsible for our customers. They give us strong support in the past ten years. Luckily, our CEM learning materials never let them down. Our company is developing so fast and healthy. Up to now, we have made many achievements. Also, the CEM study guide is always popular in the market. All in all, we will keep up with the development of the society.
Good reputation
Our CEM exam materials: Certified Energy Manager (CEM) are the most reliable products for customers. If you need to prepare an exam, we hope that you can choose our CEM study guide as your top choice. In the past ten years, we have overcome many difficulties and never give up. Fortunately, we have survived and developed well. So our company has been regarded as the most excellent seller of the CEM learning materials. We positively assume the social responsibility and manufacture the high quality study materials for our customers. Never have we made our customers disappointed about our CEM study guide. So we have enjoyed good reputation in the market for about ten years. In the future, we will stay integrity and research more useful CEM learning materials for our customers. Please continue supporting our products.
Smooth operation
Our online test engine and the windows software of the CEM exam materials: Certified Energy Manager (CEM) will greatly motivate your spirits. The exercises can be finished on computers, which can help you get rid of the boring books. The operation of the CEM study guide is extremely smooth because the system we design has strong compatibility with your computers. It means that no matter how many software you have installed on your computers, our CEM learning materials will never be influenced. Also, our CEM study guide just need to be opened with internet service for the first time. Later, you can freely take it everywhere. Also, our system can support long time usage. The durability and persistence can stand the test of practice. All in all, the performance of our CEM learning materials is excellent. Come to enjoy the pleasant learning process. It is no use if you do not try by yourself.
Life is always full of ups and downs. You can never stay wealthy all the time. So from now on, you are advised to invest on yourself. The most valuable investment is learning. Perhaps our CEM exam materials: Certified Energy Manager (CEM) can become your top choice. Our study materials have won many people's strong support. Now, they have gained wealth and respect with the guidance of our CEM learning materials. At the same time, the price is not so high. You totally can afford them. Do not make excuses for your laziness. Please take immediate actions. Our CEM study guide is extremely superior.
AEE CEM Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Industrial Systems | 6–8 | - Process energy efficiency - Compressed air, pumping, and drying systems |
| Energy Audits and Instrumentation | 10% | - Data collection and analysis - Energy performance indicators - Measurement tools and instrumentation - Audit levels and methodologies |
| Operations, Maintenance and Commissioning | 5% | - Maintenance best practices - Commissioning and retro-commissioning |
| Codes, Standards and Regulations | 5% | - Compliance and reporting requirements - Sustainability policies and frameworks - Energy efficiency codes and standards |
| Lighting Systems | 10% | - Daylighting integration - Lighting technologies and efficiency - Design and control strategies |
| Energy Savings Performance Contracting | 5% | - Guaranteed savings and risk allocation - Contract structures and financing |
| Building Automation and Controls | 5% | - Building management systems - Automation and optimization - Control systems and strategies |
| Electrical Power Systems and Motors | 15% | - Power distribution and quality - Motor systems, efficiency and controls - Power factor correction and load management |
| HVAC Systems and Building Envelope | 15% | - Thermal envelope performance - Load calculation and system selection - Heating, ventilation and air conditioning |
| Energy Accounting and Economics | 15% | - Time value of money, NPV, IRR, payback analysis - Energy units and conversions - Utility rate structures and tariffs - Life cycle costing and economic analysis |
| Boiler and Steam Systems | 4–6 | - Maintenance and optimization - Operation and efficiency |
| Measurement and Verification | 5% | - Baseline development and savings calculation - M&V protocols and standards |
| Energy Storage Systems | 3–5 | - Integration and benefits - Storage technologies and applications |
| Distributed Generation and Renewable Energy | 4–6 | - Combined heat and power (CHP) - Solar, wind, biomass, geothermal - Grid integration and economics |
AEE Certified Energy Manager (CEM) Sample Questions:
1. A high-pressure steam system passes 180°C condensate (saturated liquid) through a steam trap to an atmospherically vented condensate receiver tank. If the steam trap is working properly, how much of the condensate mass can be lost out the vent of the receiver tank in the form of flash steam?
A) 15%
B) 6%
C) 66%
D) 25%
E) 100%
2. What type of heat transfer is reduced by adding insulation to the inside surface of a wall?
A) Radiation
B) Convection
C) Conduction
3. In general, which of the following is the least expensive and easiest way to finance an energy project?
A) Debt
B) Performance contract
C) Equity
4. A concentrating solar thermal system collects 5 GJ/h of thermal heat, which is delivered to a 94% efficient hot water generator. The hot water generator is used to raise the water temperature from 15°C to 65°C. The specific heat of water (Cp) is 4.2 kJ/kg-°C. What flow rate (liter/second) of hot water can be delivered from the hot water generator?
A) 9.2 liter/second
B) 6.2 liter/second
C) 4.2 liter/second
D) 12.0 liter/second
5. A facility uses 250,000 kWh in a 31-day billing period. The peak demand in the billing period is 1,200 kW.
What is the facility partial load factor?
A) 33%
B) 28%
C) 66%
D) 45%
E) 77%
Solutions:
| Question # 1 Answer: A | Question # 2 Answer: C | Question # 3 Answer: A | Question # 4 Answer: A | Question # 5 Answer: A |